2.1 Single components for automation and testing technology
Special version LKV-S8 for establishing smaller grid sizes
Function
Function, technical features and technical data basically correspond to the LKV standard version. Please take notice that due to the smaller piston seal the clamping piston pressing force is approx. 50% lower than with the standard modules of the LKV-12 model series. Grid sizes up to 9 mm are possible due to the smaller case width (8 mm). Versions between 1,5 mm and 4 mm bonding outlet are available for single line bonding.The air plug is generally a swivelling angular connection for 3 mm hose diameter
Function
Function, technical features and technical data basically correspond to the LKV standard version. Please take notice that due to the smaller piston seal the clamping piston pressing force is approx. 50% lower than with the standard modules of the LKV-12 model series. Grid sizes up to 9 mm are possible due to the smaller case width (8 mm). Versions between 1,5 mm and 4 mm bonding outlet are available for single line bonding.The air plug is generally a swivelling angular connection for 3 mm hose diameter
Order No.:
LKV-S8 -D40FWS
Please take note of our special accessories such as pneum. central opener, compressed air distributor.
2.2 Single components for automation and testing technology
Special version for bonding thin conductors, wires, etc.
Function
The bonding outlet is closed when the compressed air is switched on. The conductor, strand, etc. can be inserted after pressing the LKT button. Conductor bonding takes place after releasing the button. Bonding is performed using a clamping piston which makes contact to the conductor.
For not bared line ends, the connection is made using a steel tip piercing through the insulation and making connection to the conductor.
Order data
To ensure safe bonding of the conductor, the bonding outlet has to be adjusted to the conductor outer diameter.
Indicate the diameter (0.1 mm precision).
We adjust the locating hole so that the conductor can be inserted easily and safe bonding is also ensured.
Order example
LKT-S8-D2,5-0F2 for conductor of 2.0 mm diameter.
We manufacture the bonding module e.g. with a 2.5 mm locating hole.
Note
In all but the case width, the dimensions correspond to the LKV-12 standard module.
Refer to the data sheet: Available types of cases.
Please take note of our special accessories such as pneum. central opener, compressed air distributor.
Function
The bonding outlet is closed when the compressed air is switched on. The conductor, strand, etc. can be inserted after pressing the LKT button. Conductor bonding takes place after releasing the button. Bonding is performed using a clamping piston which makes contact to the conductor.
For not bared line ends, the connection is made using a steel tip piercing through the insulation and making connection to the conductor.
Order data
To ensure safe bonding of the conductor, the bonding outlet has to be adjusted to the conductor outer diameter.
Indicate the diameter (0.1 mm precision).
We adjust the locating hole so that the conductor can be inserted easily and safe bonding is also ensured.
Order example
LKT-S8-D2,5-0F2 for conductor of 2.0 mm diameter.
We manufacture the bonding module e.g. with a 2.5 mm locating hole.
Note
In all but the case width, the dimensions correspond to the LKV-12 standard module.
Refer to the data sheet: Available types of cases.
Please take note of our special accessories such as pneum. central opener, compressed air distributor.
2.3 Single components for automation and testing technology
Special version LKT-S6 for establishing smaller grid sizes. Because of the low clamping piston pressure, only suitable for very thin strands and conductors.
Function
The bonding outlet is closed when the compressed air is switched on. The conductor, strand, etc. can be inserted after pressing the LKT button. Conductor bonding takes place after releasing the button. Bonding is performed using a clamping piston which makes contact to the conductor.
Order data
To ensure safe bonding of the conductor, the bonding outlet has to be adjusted to the conductor outer diameter. Indicate the diameter (0.1 mm precision). We adjust the locating hole so that the conductor can be inserted easily and safe bonding is also ensured.
Order example
LKT-S6-Dx,x-0FS for conductor of 1.5 mm diameter.
We manufacture the bonding module e.g. with a 1.9 mm locating hole.
Function
The bonding outlet is closed when the compressed air is switched on. The conductor, strand, etc. can be inserted after pressing the LKT button. Conductor bonding takes place after releasing the button. Bonding is performed using a clamping piston which makes contact to the conductor.
Order data
To ensure safe bonding of the conductor, the bonding outlet has to be adjusted to the conductor outer diameter. Indicate the diameter (0.1 mm precision). We adjust the locating hole so that the conductor can be inserted easily and safe bonding is also ensured.
Order example
LKT-S6-Dx,x-0FS for conductor of 1.5 mm diameter.
We manufacture the bonding module e.g. with a 1.9 mm locating hole.
LKT-S6 -D1,9-0FS
Note
In all but the case width, the dimensions correspond to the LKV-12 standard module.
Refer to the data sheet: Available types of cases.
Please take note of our special accessories such as pneum. central opener, compressed air distributor.